Re: 2 SCSI Controllers

From: Jeff Vian (jvian10_at_charter.net)
Date: 04/29/04

  • Next message: Adam Voigt: "Re: upgrading to postgresql 7.4 from development branch"
    Date: Thu, 29 Apr 2004 08:29:24 -0500
    To: For users of Fedora Core releases <fedora-list@redhat.com>
    
    

    Götz Reinicke wrote:

    >
    >
    > Alexander Dalloz schrieb:
    >
    >> Am Do, den 29.04.2004 schrieb Götz Reinicke um 12:07:
    >>
    >>
    >>> Hi,
    >>>
    >>> I have an Dell PE 1650 Server with an internal perc 3/di SCSI RAID
    >>> Controller hosting a RAID 1 and an Adaptec 29160 Controller hosting
    >>> an external Hardware RAID-Box.
    >>>
    >>> If I boot, and try to install Fedora, the external RAID is seen as
    >>> sda, the internal RAID as sdb.
    >>>
    >>> How can I change this order, so that the internal RAID is sda and
    >>> the external RAID is sdb? Any ideas?
    >>>
    >>>
    >>> Regards
    >>>
    >>> Götz Reinicke
    >>
    >>
    >>
    >> Just change the SCSI ID of the RAID arrays/drives. The lowest is sda,
    >> the second... Remembering your previous post about difficulties with an
    >> external SCSI driver array of SATA drives I guess you can specify the
    >> SCSI ID for the whole external box.
    >
    >
    > I do have different IDs, 0 for the internal RAID, 1 for the external
    > RAID-Box. The later is attached to a different SCSI Controller.
    >
    > But the external Box is seen as sda :-(
    >
    This is because of the sequence in which the cards are seen/configured
    on the PCI bus, as well as the scsi bus ID sequence. The scsi ID is not
    the only thing it looks at to decide what name it gives the drive.

    The general rule to decide what device gets what name is first
    configured controller, scsi id sequence on that bus, then next
    configured controller, scsi id sequence on that bus, etc.

    Thus, you can have a controller in pci slot 1 and another in slot 3. If
    the controller in slot 3 is configured first its drives take precedence
    over those on the controller in slot 1.

    If you have devices on a single controller, AFAIK they will always get
    configured in id sequence.
    This can become a problem if you leave gaps in the scsi IDs then later
    add another device that fills that ID slot. the drives at the later IDs
    will get the name changed.

    For example, you have a single scsi drive at ID 4. this will by default
    be named sda. Then you add another drive at ID 0. Now that new drive
    will be sda and the original becomes sdb. This effect can be a bit
    disconcerting at times if not expected.

    >
    > so long...
    > ...Götz

    -- 
    fedora-list mailing list
    fedora-list@redhat.com
    To unsubscribe: http://www.redhat.com/mailman/listinfo/fedora-list
    

  • Next message: Adam Voigt: "Re: upgrading to postgresql 7.4 from development branch"

    Relevant Pages

    • Re: 3B2 Disks
      ... 2 MFM drives on a custom controller. ... what it came out of) but the only SCSI I heard about on the 3B's used ... any software out and would more likely have recycled the floppy disks. ...
      (comp.sys.3b1)
    • Re: Loss of SCSI boot after CMOS battery replacement
      ... result of my old motherboard BIOS after all. ... controller takes priority over the SCSI ... IDE first to SCSI first. ... SCSI drives and Win98. ...
      (comp.periphs.scsi)
    • Re: Hot Swapping a SATA drive in Windows 2000 and XP.
      ... knowledge) that designates add-on cards as SCSI but rather the system BIOS. ... this day if you choose to boot from a HD (IDE or SATA) which is attached to ... drives attached to the built-in promise controller will most probably ...
      (microsoft.public.windowsxp.hardware)
    • Re: RAID configuration with out RAID controller
      ... disks with out scsi controller, ... That's a pretty good trick to use hard drives without a controller. ... you are saying you do not have a SCSI Array Controller so you cannot create ...
      (microsoft.public.windows.server.general)
    • Re: Strange PEER error with Danis 506 1.81 generic question
      ... First, a really large number of the systems around me are still SCSI systems which use not only SCSI hard drives, but also SCSI DAT drive tape backup systems, additional SCSI hard drives which can be plugged in, but are not normally there, in mobile drive trays; as well as, in some cases actual SCSI CD-RW units. ... The only use there for the IDE interface is another CD or DVD device for read purposes. ...
      (comp.os.os2.bugs)