From: Gene Heskett (gene.heskett_at_verizon.net)
Date: 03/08/05

  • Next message: Skunk Worx: "Re: Is Linux really faster than MS Windows ?"
    Date: Mon, 07 Mar 2005 21:48:23 -0500
    To: Brian Mury <b.mury@ieee.org>, For users of Fedora Core releases <fedora-list@redhat.com>
    
    

    On Monday 07 March 2005 20:33, mark@mark.mielke.cc wrote:
    >On Mon, Mar 07, 2005 at 04:27:57PM -0800, Brian Mury wrote:
    >> On Mon, 2005-07-03 at 17:39 -0500, mark@mark.mielke.cc wrote:
    >> > An electric heater is not 100% efficient and the components in
    >> > it are *made* to be efficient for the purposes of heating. (I'm
    >> > not even sure what 100% efficient means when converting
    >> > electricity to heat - I would think that it would mean 100%
    >> > electricity in = 100% heat out - which is not the case at all
    >> > for any sort of electrical heaters that I am familiar with)
    >>
    >> Of course an electric heater is 100% efficient. A lightbulb is not
    >> 100% efficient - it's job is to produce light, but it has loss in
    >> the form of heat. An electric heater's job is to produce heat -
    >> and it has loss in the form of what? Heat? Every bit of energy
    >> consumed by an electric heater generates heat. All of it. Every
    >> last bit.
    >> Please tell me where you think the electrical energy that is not
    >> converted to thermal energy goes.
    >
    >Well, now you can show off and explain why some heaters are more
    > efficient than other heaters. I'm interested. :-)
    >
    >Or does it not matter which heater I buy at Canadian Tire - as long
    > as I look at the capacity rating, I'll know it will cost me the
    > exact same in electrical costs?

    Yes, and it will generate the same number of calories/btu per hour as
    any other identically rated heater.

    Within the manufacturing tolerances, which could be in excess of 10%,
    yes. That 1600 Watt rated heater may draw, on a good stiff line with
    the full rated 127 volts at the socket with the heater plugged in and
    turned on, a bit over 1750 Watts, all of which will be used at 100%
    efficiency.

    OTOH, on a real crappily wired house, that may well exceed the rated
    carrying capacity of the house wireing to the plug its plugged into,
    so it will draw only 1350 Watts or so, with another 75 to 100 watts
    being dissipated in the house wireing feeding it. That will of
    course lead to a potential fire risk eventually, so I'd certainly NOT
    recommend that it be plugged into a 15 amp circuit, turned on and
    ignored for the next 10 years as the wireing *will* eventually fail.

    I've seen more than my share of older houses with a run of 14 gauge
    romex feeding a string of 6 to 8 duplexes, and a 30 amp fuse screwed
    into the socket. Thats twice the rated current carrying capacity of
    a piece of 14 gauge romex. In the event thats your situation, I'd
    make damned sure my last will and testament was up to date, and in a
    safe, offsite place.

    Even 12 gauge is only legal for 20 amps.

    In modern wireing practice, and according to the NEC codebook, the
    rating of the duplex receptacle you are looking at should be readily
    discerned as the 15 amp circuit has only the two slots and
    (hopefully) a round hole for the static ground. A 20 amp fed duplex
    should have one slot shaped like a T with the crossbar being in the
    same direction as the plain slot in the 15 amp rated device. The
    wider of the two slots is the neutral side, the narrower is the hot
    side.

    >mark (who might be full of crap in his doubt and disbelief of
    > Brian's electrical engineering logic claiming that, for a house
    > that requires heating, running a computer 24/7 is virtually
    > free...)
    >
    It is essentially and for all measurement purposes free if the rest of
    the house is also electrically heated also. Heat is heat, and the
    rest of the house isn't going to give a flip what it is that
    generates the calorie's to make up for the insulation and cold air
    insolation losses. To maintain 68F on a -10F day is gonna take x
    turns of the wheel in the meter, no more, no less.

    Electrical wireing itself may be exterior to the insulation in some
    places, in which case its losses won't generally go toward heating
    the living space, but these considerations rarely exceed more than 25
    watts per well wired house, and would be there regardless of how the
    energy input in the form of electricity was actually spent within the
    house. Heck, even the 350-400 watts the average new refrigerator
    uses to keep its interior cool, is output into the living space in
    the form of warm air, so in that sense, even the refrigerator is 100%
    efficient. Even the kilowatt plus an old box uses, is, at the end of
    the day, 100% heat into the living space.

    -- 
    Cheers, Gene
    "There are four boxes to be used in defense of liberty:
     soap, ballot, jury, and ammo. Please use in that order."
    -Ed Howdershelt (Author)
    99.34% setiathome rank, not too shabby for a WV hillbilly
    Yahoo.com attorneys please note, additions to this message
    by Gene Heskett are:
    Copyright 2005 by Maurice Eugene Heskett, all rights reserved.
    -- 
    fedora-list mailing list
    fedora-list@redhat.com
    To unsubscribe: http://www.redhat.com/mailman/listinfo/fedora-list
    

  • Next message: Skunk Worx: "Re: Is Linux really faster than MS Windows ?"

    Relevant Pages

    • Re: electric rate & fees survey
      ... the range & water heater. ... There really isn't too much that can contaminate propane that would reach the burner. ... Electricity Delivery Charges ... barns and my walk-in freezer then it'll hold the heat in and the lamp will be fine. ...
      (misc.rural)
    • Re: Mini cabi needs heat
      ... water heater in the crawl space is in a heap of trouble. ... backup heat source of choice since electricity is fairly expensive ... It is now far cheaper to heat with electric space heaters when the ... If power is unreliable during storms then you'll need actual backup heat ...
      (misc.rural)
    • Re: Propane and electric pump heat questions
      ... house that has a combination of electric pump heat and propane heat. ... based propane system about 5 years ago to reduce their heating costs. ... propane bills are $2000/year and electricity is about $4000/year. ...
      (alt.home.repair)
    • Re: What is the best heater for under $100?
      ... If the question on the table is "which type of electric heater provides the ... cheapest heat." ... but have you actually owned an oil filled radiator or is ... - Electricity is a means of moving energy from one location to another. ...
      (misc.consumers)
    • Re: Ways to Conserve Energy and Fuel
      ... I have a non-vented heater in our living room that heats the whole house. ... A regular furnace is about 85% efficient which means $15.00 of every $100.00 of your heat bill goes out the chimney. ... Your problem was, you did not have kerosene, you were using diesel fuel and that males the difference. ...
      (rec.outdoors.rv-travel)