FC6 and F7rc2 poweroff problem on server HP ML110
- From: Dario Lesca <d.lesca@xxxxxxxxxx>
- Date: Thu, 31 May 2007 13:05:54 +0200
Hi, On a HP ML 110 with this component:
[root@ca1 ~]# lspci
00:00.0 Host bridge: Intel Corporation E7230/3000/3010 Memory Controller Hub (rev c0)
00:1c.0 PCI bridge: Intel Corporation 82801G (ICH7 Family) PCI Express Port 1 (rev 01)
00:1c.4 PCI bridge: Intel Corporation 82801GR/GH/GHM (ICH7 Family) PCI Express Port 5 (rev 01)
00:1c.5 PCI bridge: Intel Corporation 82801GR/GH/GHM (ICH7 Family) PCI Express Port 6 (rev 01)
00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01)
00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01)
00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01)
00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01)
00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01)
00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1)
00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01)
00:1f.1 IDE interface: Intel Corporation 82801G (ICH7 Family) IDE Controller (rev 01)
00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01)
03:00.0 VGA compatible controller: Matrox Graphics, Inc. MGA G200e [Pilot] ServerEngines (SEP1) (rev 02)
04:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5721 Gigabit Ethernet PCI Express (rev 21)
when I push the poweroff button or I run poweroff, the system start the
shutdown procedure, but when the system is Off, after 2 or 3 seconds it
restart! .. and when it is active, some USB device not work property.
Then in order for poweroff machine and do work USB device, i must
remove the power cable when the system is shutdown!!....
If I install on this server FC5 all work great.
There is a solution to this problem of FC6?
I have also install on this HP system F7rc2: with this version of Fedora
all work fine, but the poweroff via Button Press not work, I have see
witch acpid is not installed by default and there is run a new (for me)
process called
"hald-addon-acpi: listening on acpi kernel interface /proc/acpi/event"
Is this process that it would have to be taken care to poweroff the
system? why do not do it?
Thank for your reply.
--
Dario Lesca <d.lesca@xxxxxxxxxx>
--
fedora-list mailing list
fedora-list@xxxxxxxxxx
To unsubscribe: https://www.redhat.com/mailman/listinfo/fedora-list
- Prev by Date: Re: r300 driver stability
- Next by Date: Re: r300 driver stability
- Previous by thread: Using screenshots of emacs and bash in a book
- Next by thread: time to 64bit?
- Index(es):