From: Ed Wilts (ewilts_at_ewilts.org)
Date: 04/03/05

  • Next message: mark: "X crashing"
    Date: Sun, 3 Apr 2005 09:46:15 -0500
    To: General Red Hat Linux discussion list <redhat-list@redhat.com>
    
    

    On Sun, Apr 03, 2005 at 05:56:47AM -0700, Brian D. McGrew wrote:
    > You'll either need an APC ShareUPS which is basically a serial splitter
    > that does smart signaling to one server for UPS monitoring and dumb
    > signaling to the rest of the servers for shutdown ... OR ... You can get
    > a UPS that has SNMP capabilities that all your servers can monitor.

    There are a few open source projects out there that do distributed UPS
    management - one server listens for the UPS events and then the other
    clients act based on the information they get from that server.

    http://us1.networkupstools.org/
    http://freshmeat.net/projects/inpowerd/

            ../Ed

    > -----Original Message-----
    > From: redhat-list-bounces@redhat.com
    > [mailto:redhat-list-bounces@redhat.com] On Behalf Of Pete Nesbitt
    > Sent: Saturday, April 02, 2005 10:07 PM
    > To: General Red Hat Linux discussion list
    > Subject: Re: APC2200 and Linux
    >
    > On Saturday 02 April 2005 8:38 pm, Robert Canary wrote:
    > > I am trying to figure out how to install and
    > > configure PowerChute on a Redhat system and use it
    > > to notify other servers(on the same ups) to
    > > shutdown. APCs documentation is terrible (of what
    > > I have found). The installatoin gose fine. But
    > > how do I get to the control panels, and set up
    > > other machines to be a slave?
    > >
    > > I see no way to configure the PowerChute or
    > > control it. This is really aggravating, as I was
    > > needing to have this done before Sun 12(noon)
    > > (trying to go on vacation). And I have been
    > > studying on this for 4 days already.
    > >
    > > What is everyone using to control an APC
    > > Master/Slave PC?
    > >
    > > thanks in advance
    > >
    > > --
    > > robert canary
    > > system services
    > > OCDirect.Net
    > > (270)298-9331 (o)
    >
    > Not sure about that model, but usually you'll need to connect to the ups
    > via
    > the serial connection to set it up. Even if it has a web interface,
    > you'll
    > probably need to first connect via telnet on a serial line.
    >
    > We have a APC Symmetra and I use the powerchute 'network shutdown'
    > software.
    > IIRC, after initial set up of the UPS, I can install the PowerChute
    > software
    > on a server, then go to the web interface to the UPS (or telnet in) and
    > tell
    > it to connect to and add the IP address of the server to the list of
    > systems
    > to notify. However, the different models may use different iterations of
    >
    > PowerChute.
    >
    > --
    > Pete Nesbitt, rhce
    > www.linux1.ca

    -- 
    Ed Wilts, RHCE
    Mounds View, MN, USA
    mailto:ewilts@ewilts.org
    Member #1, Red Hat Community Ambassador Program
    -- 
    redhat-list mailing list
    unsubscribe mailto:redhat-list-request@redhat.com?subject=unsubscribe
    https://www.redhat.com/mailman/listinfo/redhat-list
    

  • Next message: mark: "X crashing"

    Relevant Pages

    • Re: Server off line - No reason
      ... I replaced the batteries on all the APC right ... I have open the circuit breaker for the outlets and the server is fine. ... even when I had the UPS connect to the server. ... >>> UPS is gone if you have building power problems you would still be ...
      (microsoft.public.windows.server.sbs)
    • Re: UPS Hardware
      ... spend the bucks and get APC. ... I am installing an APC Smart UPS 1500 acquired after discovering a smaller ... down the server after the specified time. ... The PowerChute console shows the ...
      (microsoft.public.windows.server.sbs)
    • Re: Server off line - No reason
      ... WOW the server has gone two more times since yesterday. ... The APC are the are same one that I have used for two years. ... three p/s all plug into seperate UPS. ... > UPS is gone if you have building power problems you would still be ...
      (microsoft.public.windows.server.sbs)
    • Re: APC PowerChute Business Edition Lost Connection
      ... I believe one of the MVP's here uses this and never installs ... the bundled software that comes with APC UPS device. ... didnt see any performance increase from the server. ...
      (microsoft.public.windows.server.sbs)
    • RE: APC2200 and Linux
      ... You'll either need an APC ShareUPS which is basically a serial splitter ... that does smart signaling to one server for UPS monitoring and dumb ... a UPS that has SNMP capabilities that all your servers can monitor. ... > configure PowerChute on a Redhat system and use it ...
      (RedHat)