APC UPS and apcupsd help

From: Jack Frillman (jack_at_dnaco.net)
Date: 10/23/04


Date: Sat, 23 Oct 2004 17:04:28 -0400


I have tried asking for help with this problem to the author and the
mailing list at sourcefourge but I have not received a response.

Soooooooooo I will try here....

I am trying to get apcupsd working on Fedora Core 2 with an APC backUPS
725 ES series UPS.
I successfully configured, compiled, installed and started apcuspd as a
simple one computer one UPS
configuration. I even get what appears to be valid the output
from running apcaccess status. See below:

[root@localhost root]# apcaccess status
APC : 001,033,0846
DATE : Sat Oct 16 13:36:24 EDT 2004
HOSTNAME : localhost.localdomain
RELEASE : 3.10.15
VERSION : 3.10.15 (04 August 2004) redhat
UPSNAME : localhost.localdomain
CABLE : USB Cable
MODEL : Back-UPS ES 725
UPSMODE : Stand Alone
STARTTIME: Sat Oct 16 13:36:23 EDT 2004
STATUS : ONLINE
LINEV : 118.0 Volts
LOADPCT : 59.0 Percent Load Capacity
BCHARGE : 090.0 Percent
TIMELEFT : 8.8 Minutes
MBATTCHG : 5 Percent
MINTIMEL : 3 Minutes
MAXTIME : 0 Seconds
LOTRANS : 088.0 Volts
HITRANS : 138.0 Volts
ALARMDEL : Always
BATTV : 13.4 Volts
NUMXFERS : 0
TONBATT : 0 seconds
CUMONBATT: 0 seconds
XOFFBATT : N/A
STATFLAG : 0x02000008 Status Flag
MANDATE : 2003-02-07
SERIALNO : QB0306263747
BATTDATE : 2000-00-00
NOMBATTV : 12.0
FIRMWARE : 02.n2.D USB FW:n2
APCMODEL : Back-UPS ES 725
END APC : Sat Oct 16 13:36:30 EDT 2004
[root@localhost root]#

I have gone through the manual and everything was going fine until I
began the "Communications Test" .
At this point I was unable to get the predicted results. When I
disconnect the USB cable from the UPS a wall message is not
sent and no apcupsd event messages are logged to apcupsd.events or
/var/log/messages. The only messages I see logged are the
disconnect and re-connect of a USB device in /var/log/messages. The
manual says correct this before continuing unless you have a dumb UPS.

Thinking that maybe the UPS I have is not as smart as I thought I proceeded
to the "Simulated Power Test" and I did not get the expected results either.
In other words no event messages were loged or sent to a console.

How do I correct the Communications test failure?
The manual says to correct it before contuning but does not give any
guidance on how.

Some other things I noticed and did to get to this point.

1) BATTV is 13.4 Volts instead of the "...should be near 24 volts...."
as stated in the manual. I am only using one battery. Don't know if this
has anything to do with it or not.
2) When I first tried starting apcupsd I specified a 940-1227A cable but
apcupsd would not start. When I changed this to USB it started. The USB
cable I have is stamped 940-1227B.

Thanks,

Jack



Relevant Pages

  • [SLE] APCUPSD (Battery Backup) Question
    ... Running SuSE 9.3 with an APC BX1000 UPS. ... When I disconnect the USB cable apcupsd is supposed to report that it has ... lost connection with the UPS. ... LOTRANS: 097.0 Volts ...
    (SuSE)
  • UPS on FreeBSD
    ... I have attached a UPS to FreeBSD host using USB cable provided by APC. ... addr 1: UHCI root hub, ...
    (freebsd-questions)
  • Re: apcupsd with usb
    ... >usb support in apcupsd since afaik only usb with linux is still supported. ... CABLE: Custom Cable Smart ... LOTRANS: 088.0 Volts ... APCMODEL: Back-UPS ES 725 ...
    (freebsd-questions)
  • Re: [opensuse] Attempting (and failing) to use my UPS
    ... I'm attempting to make use of my new UPS, connecting it via USB to the ... ACL localhost 127.0.0.1/32 ... NOTIFYFLAG ONLINE SYSLOG ...
    (SuSE)
  • Re: FreeBSD and UPS APC RS 1000
    ... from the UPS, It can do things like UPS shutdown which is handy. ... remove uhid from the kernel config and make sure ugen is in there. ... Edit the conf file to reflect that you have it configured for a USB ... # NISPORT default is 3551 as registered with the IANA ...
    (comp.unix.bsd.freebsd.misc)