Re: Raid5 software problems after loosing 4 disks for 48 hours



wilson wrote:

I run a 15 disk raid5 array. Unknowingly a contoller card failed which
had 4 disks on it. And unfortunatly the Raid5 stayed online, doing its
best.

Now after replacing the controller the raid can not be brought on line.
I would rather have corruption of anything changed on the array in the
last 2 days then loose 4 disks.

Quote:
# mdadm --examine /dev/sdc1
/dev/sdc1:
Magic : a92b4efc
Version : 00.90.01
UUID : eed326c4:6cf58a43:d1b57676:5b765f6c
Creation Time : Sun Nov 13 16:07:21 2005
Raid Level : raid5
Raid Devices : 15
Total Devices : 15
Preferred Minor : 0

Update Time : Mon Jun 12 11:08:09 2006
State : clean
Active Devices : 11
Working Devices : 11
Failed Devices : 8
Spare Devices : 0
Checksum : c967848b - correct
Events : 0.5456277

Layout : left-symmetric
Chunk Size : 32K

Number Major Minor RaidDevice State
this 1 8 33 1 active sync /dev/sdc1

0 0 8 17 0 active sync /dev/sdb1
1 1 8 33 1 active sync /dev/sdc1
2 2 8 49 2 active sync /dev/sdd1
3 3 0 0 3 faulty removed
4 4 0 0 4 faulty removed
5 5 0 0 5 faulty removed
6 6 0 0 6 faulty removed
7 7 8 129 7 active sync /dev/sdi1
8 8 8 145 8 active sync /dev/sdj1
9 9 8 161 9 active sync /dev/sdk1
10 10 8 177 10 active sync /dev/sdl1
11 11 8 193 11 active sync /dev/sdm1
12 12 8 209 12 active sync /dev/sdn1
13 13 8 225 13 active sync /dev/sdo1
14 14 8 241 14 active sync /dev/sdp1


All the disks are online now, what do I need to do to rebuild the array?
And is there a way if more then 1 disks goes offline, for the whole
array to be taken offline? My understanding of raid5 is loose 1+ disks
and nothing on the raid would be readable. this is not the case here.


Your running software RAID5?


dnoyeB
.



Relevant Pages

  • Re: hardware raid 1, 5 question
    ... is raid 1 any faster, slower or the same as raid 5? ... complicated mode of operation, but a soft RAID1 ... RAID5 performance really depends on a couple things. ... recommend using four disks. ...
    (microsoft.public.windowsxp.hardware)
  • RE: Linux MD RAID 5 Benchmarks Across (3 to 10) 300 Gigabyte Veliciraptors
    ... Linux MD RAID 5 Benchmarks Across 300 Gigabyte ... RAID5 disk set. ... # Disable NCQ on all disks. ... echo "Disabling NCQ on all disks..." ...
    (Linux-Kernel)
  • Re: RAID Performance
    ... "Jim" schrieb im Newsbeitrag ... > Our array is RAID5. ... > included within one LV on the RAID. ... Even if these four disks are available for the RAID itself (and not ...
    (comp.unix.aix)
  • Re: Raid5 software problems after loosing 4 disks for 48 hours
    ... And unfortunatly the Raid5 stayed online, ... Now after replacing the controller the raid can not be brought on line. ... last 2 days then loose 4 disks. ...
    (comp.os.linux)
  • Re: DC RAID Configuration
    ... If the machine has 6 spindles then OS/Logs go on a hardware mirror, if 10 then they go on a 4 disk hardware based 0+1 RAID. ... Their DIT is only in the teens in size so the disks themselves could be small, you just need many to get the high IOPS that make AD really run smoothly. ... 30 DCs with 2500 users total, unless the environment had a lot of very heavy use AD apps I would likely be ok for even a single mirror for those DCs. ...
    (microsoft.public.win2000.active_directory)